6. RAS Information


6.3 Trouble shooting

When AS311 does not work properly, check the following points.



When AS311’s RUN

Does the POWER LED on

If no, check the power

LED does not light;

the T3 power supply module

voltage/connection.

light

?

If no, check the internal

5 Vdc current

consumption.


Is the AS311 mounted

Remove the AS311,

securely on the base ?

and mount again

securely.


When RX1/RX2 LED

Are the transmission

Check the cable

does not light while

signals (RXD, SG, etc.)

connection.

the connected device is

connected properly ?

transmitting a message;


When the received data

Does the receive error

Check the transmission

cannot be read properly;

occur ?

parameters (baudrate,

parity,

etc.).


Check the cable

connection.


Confirm the receive

error

information.


Is the T3 program working

Check the T3 program.

correctly

?


When a data cannot be

Does the transmit error

Confirm the transmit

transmitted from the

occur ?

error information.

AS311 (TX1/TX2 LED

does not light);

Check the T3 program.


Is the CTS signal

Check the cable

connected properly ?

connection.

If CTS signal is OFF,

data

transmitting

is

prohibited.

Advertising