background image

Syntax and Commands

3-78

AFG3000 Series Arbitrary/Function Generators Reference Manual

[SOURce[1|2]]:SWEep:MODE

The [SOURce[1|2]]:SWEep:MODE command selects auto or manual for the sweep
mode for the specified channel.

The query command returns the sweep mode for the specified channel.

Group

Source

Related Commands

[SOURce[1|2]]:SWEep:HTIMe
[SOURce[1|2]]:SWEep:RTIMe
[SOURce[1|2]]:SWEep:TIME
TRIGger[:SEQuence]:SOURce
TRIGger[:SEQuence]:TIMer

Syntax

[SOURce[1|2]]:SWEep:MODE {AUTO|MANual}

[SOURce[1|2]]:SWEep:MODE?

Arguments

AUTO sets the sweep mode to auto. The instrument outputs a continuous sweep at
a rate specified by Sweep Time, Hold Time, and Return Time.

MANual sets the sweep mode to manual. The instrument outputs one sweep when
a trigger input is received.

Returns

AUTO|MAN

Examples

SOURce1:SWEep:MODE AUTO
sets the CH1 sweep mode to auto. The instrument outputs a continuous sweep.

Advertising