TransAct Technologies ITHERM 280 User Manual

Page 136

Advertising
background image

Programming Codes

iTherm

®

280 Programmer’s Guide

Page 134

Rev C

28-07764

Function

Load item from user store

ASCII

[ESC] [US] l <Name..> <0>

Hexadecimal 1BH 1FH 6CH
Decimal

<27> <31> <108>

IPCL

&%UL <Name..> <0>

EPOS

[GS] 0<Name..> <0> is from one to 15 characters and must be null terminated.

Description The [ESC] [US] l <Name..> <0> command loads the referenced item into the

appropriate structure. If the item referenced is a user-defined character set, it is
loaded into the current user-character definition, which does not affect the active
state of user-defined characters. If it is a macro, it is loaded into the macro
buffer, but it is not inserted into the data stream. [ESC] g <0> inserts the macro
buffer into the data stream. If the named item does not exist, the command does
nothing.

The terminating <0> may be replaced with an & or redefined. See [ESC]
[EM]T<n> or &%UT>n> on page 136.

Function

Run macro data from user store

ASCII

[ESC] [US] r <Name..> <0>

Hexadecimal 1BH 1FH 72H
Decimal

<27> <31> <114>

IPCL

&%UR <Name..> <0>

EPOS

[GS] 0<Name..> <0> is from one to 15 characters and must be null terminated.

Description The [ESC] [US] r <Name..> <0> command loads the referenced macro into the

macro buffer. The macro buffer is then inserted into the data stream. If the
named item does not exist or is not a macro, nothing happens.

The terminating <0> may be replaced with an & or redefined. See [ESC]
[EM]T<n> or &%UT<n> on page 136.

Function

Flag item as a start-up macro

ASCII

[ESC] [US] s <Name..> <0>

Hexadecimal 1BH 1FH 73H
Decimal

<27> <31> <115>

IPCL

&%US <Name..> <0>

EPOS

[GS] 0<Name..> <0> is from one to 15 characters and must be null terminated.

Description The [ESC] [US] s <Name..> <0> command flags the referenced item to be

processed at startup. Only one user character definition and one macro may be
flagged to run at startup.

Note: If a character definition is loaded at startup, it is automatically made
active.

The terminating <0> may be replaced with an & or redefined. See [ESC]
[EM]T<n> or &%UT<n> on page136

Function

Delete item from user store

ASCII

[ESC] [US] d <Name..> <0>

Hexadecimal 1BH 1FH 64H
Decimal

<27> <31> <100>

Advertising