Programming Codes

iTherm

®

280 Programmer’s Guide

Page 222

Rev C

28-07764

Decimal

<29> <72> <n>

Range

0

n

3, 48

n

51

Description The GS H <n> command selects the printing position of HRI (Human Readable

Interpretation) characters when printing a bar code. <n> selects the printing
position as follows.

<n>

Printing position

0, 48

Not printed

1, 49

Above bar code

2, 50

Below bar code

3, 51

Both above and below the bar code

Table 43 Printing Position of HRI Characters

Function

Select Font for HRI Characters

ASCII

GS f <n>

Hexadecimal 1DH 66H <n>
Decimal

<29> <102> <n>

Range

<n> = 0, 1, 48, 49

Description The GS f <n> command selects a font for the HRI (Human Readable

Interpretation) characters used when printing a bar code. <n> selects a font from
the following table.

<n>

Font

0, 48

Font A (14 x 12)

1, 49

Font B (12 x 12)

Table 44 Font for Human Readable Interpretation (HRI) Characters

Function

Set Bar Code Width

ASCII

GS w <n>

Hexadecimal 1DH 77H <n>
Decimal

<29> <119> <n>

Range

2

n

6

Description The GS w <n> command sets the size of the bar code as follows.

N

Multi-level bar code

Binary-level bar code

Module width (mm)

Thin element width (mm)

Thick element width (mm)

2

0.250

0.250

0.626

3

0.375

0.375

1.001

4

0.500

0.500

1.251

5

0.626

0.626

1.627

6

0.751

0.751

2.002

Table 45 Horizontal size of the bar code

Advertising