iTherm

®

280 Programmer’s Guide

Page 88

Rev C

28-07764

[VT]

Vertical tab


ASCII

[VT]

Hexadecimal 0BH
Decimal

<11>

IPCL

&%VT

EPOS

(VT)

Description The printer sets a line counter to the top of the form at reset and when a

set top of form command is issued. By setting vertical tab stops, various
form positions can be reached with a [VT] operation.

[ESC] B

Set vertical tab stops


ASCII

[ESC] B <n

1

> <n

2

> <n

3

> ... <n

i

> 0

Hexadecimal 1BH 42H <n

1

> <n

2

> <n

3

> ... <n

i

> 00H

Decimal

<27> <66> <n

1

> <n

2

> <n

3

> ... <n

i

> <0>

IPCL

none

EPOS

[ESC] B <n

1

> <n

2

> <n

3

> ... <n

i

> 0

Description The [ESC] B <n

1

> <n

2

> <n

3

> ... <n

i

> 0 command sets tab stops at line

positions specified by <n>. The end of the setting is specified by a <0>.
All previously set tabs will be cleared. If n

n

is less than n

n-1

, then the

command is in error, and all of the following information is printed. In
other words, tab stops must be entered sequentially in order to be
accepted. A total of 64 tab stops can be specified. (The power on default
is a vertical tab on every line).

[ESC] R

Reset horizontal and vertical tab stops


ASCII

[ESC] R

Hexadecimal 1BH 52H
Decimal

<27> <82>

IPCL

&%HV

EPOS

none

Description The [ESC] R command resets horizontal and vertical tab stops to power

up configuration. The power up horizontal default is every eight spaces,
i.e., 9, 17, 25, etc. The vertical default is every line.