Bit

Off/On

Hex

Decimal

Status

0

Off

00H

<0>

Drawer kick-out connector pin 3 low

On

01H

<1>

Drawer kick-out connector pin 3 high

1-3

-

-

-

Undefined

4

Off

00H

<0>

Not used; fixed to Off

5,6

-

-

-

Undefined

7

Off

00H

<0>

Not used; fixed to Off

Table 34 Drawer Kick-out Connector Status (<n> = 2, 50)

Function

Transmit Real-Time Status

ASCII

[DLE] [EOT] <n>

Hexadecimal 10H 04H <n>
Decimal

<16> <4> <n>

Range

1

n

4

Description The [DLE] EOT <n> command transmits the specified status in real time. The

command is executed if the printer is off line, the print buffer is full, or an error
occurs. If the printer goes off line due to a paper-end condition, bit 5 of the
printer status (waiting for on-line recovery) is on from the time the paper roll is
inserted to the time the printer goes on-line. See the [GS] z 0 command for
details of the on-line recovery wait time. The paper roll low sensor is an option.
If the printer does not have a paper low sensor, bits 2 and 3 of the paper roll
sensor status will always be “Paper adequate.” Bit 3 of the second byte is always
“No error occurred.”

<n>

Function

1

Transmit printer status

2

Transmit off line status

3

Transmit error status

4

Transmit paper roll sensor status

Table 35 Values for the Status Function, <n>

Bit

Off/On

Hexl

Decimal

Status

0

Off

00H

<0>

Not used; fixed to off

1

On

02H

<2>

Not used; fixed to on

2

Off

00H

<0>

Drawer kick-out connector pin 3 low

On

04H

<4>

Drawer kick out connector pin 3 high

3

Off

00H

<0>

On-line

On

08H

<8>

Off line

4

On

10H

<16>

Not used; fixed to on

5

-

-

-

Undefined

6

-

-

-

Undefined

7

Off

00H

<0>

Not used; fixed to off

Table 36 Printer Status (<n> = 1)