TransAct Technologies ITHERM 280 User Manual

Page 150

Advertising
background image

Programming Codes

iTherm

®

280 Programmer’s Guide

Page 148

Rev C

28-07764

Function

Set bar code justification, human readable interpretation (HRI)
character print mode, and print direction

ASCII

[ESC] [EM] J <n>

Hexadecimal 1BH 19H 4AH <n>
Decimal

<27> <25> <74> <n>

IPCL

&%BJ <m

1

> <m

2

>

EPOS

none

The power on default is center justified with HRI characters not printed.

Description The [ESC] [EM] J <n> command selects the operation of the bar code

justification, HRI characters, and print direction.

Where n bits n

IPCL 76543210

------xx

Justified

0

00

------00

Left

1

01

------01

Center

2

02

------10

Right

--xx----

HRI characters

0

00

--00----

Not printed

16

16

--01----

Printed above the bar code

32

32

--10----

Printed below the bar code

48

48

--11----

Printed above and below the bar code

-x------

Vertical print mode. (Page mode may

work better)

0

00

-0------

Bar code printed in horizontal

direction (default)

64

64

-100----

Bar code printed in vertical direction

Note 1: The [ESC] [EM] J <n> command only affects bar code printing.

Note 2: HRI is not available in vertical print mode. You may print normal
barcodes in page mode, which will provide for HRI and significantly longer
barcodes.