E.164 address registration – Vanguard Managed Solutions Vanguard 7300 Series User Manual

Page 129

Advertising
background image

Operating Your Vanguard 7300

4-19

Vanguard 7300 Port Configuration

Configuring the
Block Alerting
Parameter

The Block Alerting parameter is accessed using the H.323 Options. To configure
your H.323 Virtual Port for Block Alerting, select H.323 Options from the Virtual
Port Parameters, and then type BLOCK ALERTING.

This table shows the range, default, and description of the H.323 Options:

E.164 Address Registration

Description

The H.323 version 2 gateway now supports the registration of E.164 numbers with
the gatekeeper for phones connected directly to the gateway.

FXS/FXO Interface
Types

The E.164 address registration feature is applicable only with FXO/FXS interface
types. E164 address registration can be configured on either a voice port or virtual
voice port.

H.323 Options

Range

NONE, DISABLE_FAST_START,
DISABLE_H245_TUNNELING, BLOCK_SETUP_ACK,
BLOCK_PROGRESS, PREPEND_CALLING_TO_CALLED,
BLOCK_ALERTING

Default

NONE

Description

The H.323 Options parameters allows you to specify H.323
Version 2 features that allows for:

• DISABLE_FAST_START - The Vanguard H.323 Version 2

implementation supports FAST START or FAST CONNECT
and automatically opens audio channels. If the H.323 Options
parameter is configured for DISABLE_FAST_START, FAST
START is not used.

• DISABLE_H245_TUNNELING - The Vanguard H.323

Version 2 implementation automatically enables tunnelling of
H.245 messages over a H.225 TCP session. If H.323 Options
parameter is configured for DISABLE_H245_TUNNELING,
H.245 messages are not tunnelled over the H.225 TCP
session. Instead a separate TCP session is used for H.245
messages.

• BLOCK_SETUP_ACK - This prevents the Q.931 SETUP

ACK message from being transmitted.

• BLOCK_PROGRESS - This prevents the Q.931 PROGRESS

Message from being transmitted.

• PREPEND_CALLING_TO_CALLED - This function copies

the calling number to beginning of the called number.

• BLOCK_ALERTING - This function prevents the Q.931

ALERTING Message from being transmitted.