Installation

3–14

445-0089-01-01

The PROsine is shipped with the screw in the position that enables the automatic
bonding system.

To disable the system, move the screw to the other hole.

Do not remove the screw from the product: make sure it is always installed in
one position or the other, as appropriate for the configuration of the rest of the
system.

Table 3-4 AC Output Neutral-to-Ground Bonding Screw Settings

Bonding Screw
Setting

Status of Bonding
Internal to the PROsine

Neutral Bonding Required
External to the PROsine

AC shorepower not
present (unit Inverting
or in Standby)

AC shorepower present
(unit Charging or in
Standby)

In the AC input
shorepower
source

In the AC load
panel

Automatic
bonding

Output neutral bonded

Output neutral
un-bonded

Yes

No

Un-bonded in
all modes

Output neutral un-
bonded

Output neutral un-
bonded

No

Yes