Step 6: connecting the ac output wires, Connections for hardwire option – Xantrex Technology PROsine 2.0 User Manual

Page 57

Advertising
background image

Step 6: Connecting the AC Output Wires

445-0089-01-01

3–15

Step 6: Connecting the AC Output Wires

Two options are available for AC output wiring:

Hardwire output.

Single hardwire output plus GFCI receptacle.

Connections for Hardwire Option

To make the AC output wiring connections

1. Run 10AWG 2-conductor-plus-ground cable through one of the cable clamps

on the AC end.

2. Strip about two inches of the jacket from the AC cable and separate the three

wires. Strip insulation from each of the wires according to the guidelines
given by the connector manufacturer.

3. Connect the outgoing black and white (line and neutral) AC wires to the

PROsine AC output black and white wires.

4. Connect the incoming ground wire to the chassis using one of the screws

marked .

5. Connect the outgoing AC wires to an AC load panel equipped with circuit

breakers.

Figure 3-5 Hardwire AC Output Option (Top, cutaway view of wiring

compartment)

Cutaway view of
PROsine wiring
compartment as
seen from the top.

wire nuts or crimp

connections (depending

on type of installation)

clamp

for AC cable

grounding screw

AC cable

Advertising