Using the ad8hr/ad824 – Yamaha 006IPTO-F0 User Manual

Page 287

Advertising
background image

Using the AD8HR/AD824

287

DM1000 Version 2—Owner’s Manual

Other Functions

20

Using the AD8HR/AD824

The Yamaha AD8HR/AD824, an 8-channel AD converter, enables you to control its gain
and phantom power from a connected DM1000. The DM1000 can control up to four
AD8HR/AD824s simultaneously.

If you connect the DM1000 to the AD8HR/AD824 digitally, and connect the DM1000
REMOTE connector to the AD8HR/AD824 REMOTE connector using a serial cable, you
can use the AD8HR/AD824 as AD Inputs for which you can preset the gain.

This section describes how to connect and configure the DM1000 and two AD8HRs.

1 Install a digital I/O card in a DM1000 slot.

If you plan to connect an AD824, install a digital I/O card on the AD824.

2 Connect the DM1000 and AD8HRs as follows.

Connection methods and cables vary depending on the specifications of the devices. The
following illustration is an example of a system in which two AD8HRs are connected via
MY8-AE cards.

Tip: You cannot store the Phantom power setting as a Scene on the DM1000.

Note:
• Set the AD8HR PC/RS422 switches to “RS422.” (If these switches are set to “PC,” the system

will not work correctly.)

• To control multiple AD8HRs or AD824s, connect the DM1000 and the AD8HRs or AD824s

in daisy chain. If you are using both AD8HR and AD824, make sure that you connect the
AD8HR closer to the DM1000.

AUX

PAN

DISPLAY

ASSIGN

ENCODER MODE

EQUALIZER

LOW

HIGH

GAIN

Q

FREQUENCY

LOW MID

HIGH MID

ROUTING

1

2

3

4

5

6

7

8

STEREO

DIRECT

DISPLAY

DISPLAY

SELECTED CHANNEL

16

BUS

8

32

48

15

BUS

7

31

47

14

BUS

6

30

46

13

BUS

5

29

45

12

BUS

4

28

44

1 1

BUS

3

27

43

10

16

15

14

13

12

1 1

10

20dB

ON

OFF

+48V

1

2

3

4

5

6

7

8

12

13

14

15

16

9

10

11

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

PEAK

SIGNAL

1

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

-16

-60

GAIN

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PEAK

SIGNAL

PAD

20dB

20dB

20dB

20dB

20dB

20dB

20dB

20dB

20dB

20dB

20dB

20dB

20dB

20dB

20dB

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

ON

OFF

+48V

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

AUX

1

1

1

17

33

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

AUX

2

2

2

18

34

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

AUX

3

3

3

19

35

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

AUX

4

4

4

20

36

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

AUX

5

5

5

21

37

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

AUX

6

6

6

22

38

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

AUX

7

7

7

23

39

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

AUX

8

8

8

24

40

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

BUS

1

9

9

25

41

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

0

5

10

15

20

30

40

50

60
70

50

40

30

20

15

10

+10

5

0

5

ON

SOLO

SEL

ON

SOLO

SEL

ON

SOLO

SEL

ON

SOLO

SEL

ON

SOLO

SEL

ON

SOLO

SEL

BUS

2

26

42

AUTO

ON

SEL

STEREO

70

60

50

40

30

20

15

10

5

0

AUX

2

AUX

3

AUX

4

AUX

6

AUX

5

AUX

7

AUX

8

AUXSELECT

DISPLAY

AUX

1

FADER MODE

FADER

AUX

DISPLAY ACCESS

AUTOMIX

DIO

SETUP

UTILITY

MIDI

REMOTE

METER

VIEW

PAIR/GROUP

INPUT

OUTPUT

EFFECT

SURROUND DYNAMICS

SCENE

/

PAN/

INSERT/ DELAY

PATCH

PATCH

GRAB

SCENE MEMORY

STORE

RECALL

DISPLAY

USER DEFINED
KEYS

ENTER

INC

DEC

TALKBACK LEVEL

PHONES

LEVEL

0

10

0

10

PHONES

MONITOR

LEVEL

SOLO

CLEAR

2TR D1

2TR D2

DIMMER TALKBACK

MONITOR

STEREO

SLOT

BUS

DISPLAY

10

0

F

1

F

2

F

3

F

4

0

OVER

-2

-4

-6

-8

-10

-12

-14

-18

-24

-30

-36

-42

-48

-56

-72

0

OVER

-2

-4

-6

-8

-10

-12

-14

-18

-24

-30

-36

-42

-48

-56

-72

L

R

+48V

HPF

dB

96kHz

88.2kHz

48kHz

44.1kHz

+48V

OFF ON

MASTER

WORD CLOCK

+48V

HPF

dB

96kHz

88.2kHz

48kHz

44.1kHz

+48V

OFF ON

MASTER

WORD CLOCK

MY8-AE

etc.

SLOT 1

AD8HR

IN

DIGITAL OUT A

REMOTE
connector

HA REMOTE
connector 1

AD8HR

SLOT 2

IN

MY8-AE

etc.

HA REMOTE
connector 2

DIGITAL OUT A

DM1000 (Master)

HA REMOTE
connector 1

Advertising
This manual is related to the following products: