3 Press the DISPLAY ACCESS [SETUP] button repeatedly until the Setup |

Remote page appears.

This page contains the following parameters:

A

REMOTE FUNCTION
This parameter selects a device to be connected to the DM1000 REMOTE connector.

B

HA section
This section enables you to specify the slot channels that will receive eight channel sig-
nals from AD8HR/AD824s that have their ID numbers set to 1 through 4.

C

HA CONTROL section
This section enables you to set the AD8HR/AD824 channel 1–8 gain and the Phantom
power on or off.

ID #1–#4........................ These buttons select the AD8HR/AD824s you want to control.

1–8 (1st row)................. These parameter controls adjust the gain for AD8HR/AD824

channels 1–8.

+48V .............................. When you turn on these buttons, the phantom power on the

corresponding channels will be turned on.

1–8 (2nd row)............... These parameter controls adjust the cut-off frequency of the

high-pass filter for the corresponding channels. They are
grayed out and cannot be set for the AD824.

HPF................................ When you turn on these buttons, the high-pass filter on the

corresponding channels will be turned on. They are grayed out
and cannot be set for the AD824.

4 Make sure that the REMOTE FUNCTION parameter is set to “HA,” and in the

HA section select the slot channels that receive signals from the
AD8HR/AD824s.

5 Use the parameter controls and buttons in the HA CONTROL section to set

the channel gain, turn on/off the phantom power, and adjust the high-pass
filter.