Tilted Sondes

If the Sonde is tilted, one Pole will move closer to the Sonde

and the other farther away.

If the Sonde is vertical what is seen on the screen is a single

Pole at the point of maximum Signal Strength. (The Ridgid

Floating Sonde is designed to have a single Pole “visible”

and is weighted to maintain the Sonde on a vertical axis.)

Maximizing the Signal Strength will still guide to the best

location for the Sonde.

Floating Sondes

Some Sondes are designed to be flushed or to drift down

a pipe pushed by water flow. The only guarantee of having

located a floating Sonde is maximizing the Signal Strength

and double checking that the signal falls away on every side

of the maximum signal location.

Measuring Depth (Sonde Mode)

The SR-20 calculates Measured Depth by comparing the

strength of the signal at the lower antenna to the upper

antenna. Measured Depth is approximate; it will usually

reflect the physical depth when the mast is held vertical and

the bottom antenna is touching the ground directly above

the signal source, assuming no distortion is present.

1. To measure depth, place the locator on the ground,

directly above the Sonde or the line.

2. Measured Depth will be shown in the lower left hand

corner of the SR-20’s display screen.

3. A Measured Depth reading can be forced by pressing

the Select Key during a locate.

4. Measured Depth will be accurate only if the signal is

undistorted.

Clipping (Sonde Mode)

Occasionally the Signal Strength will be strong enough that

the receiver will be unable to process the entire signal, a

condition known as “clipping”. When this occurs, a warning
symbol

will appear on the screen. It means that the

signal is particularly strong.

NOTE: Measured Depth Display is disabled under clipping

conditions.