seekTech sR-20

Starting Up

After pressing the Power Key

on the keypad, the RIDGID

logo displays, and the software version number will appear

on the left of the screen.

Figure 9: Start-up Screen

Set Up

Once the SR-20 is up and running the next step is to set up

the frequencies needed that match the transmitter or line to

be located.

Checked-Active frequencies are already selected for use and

appear in sequence by pressing the Frequency Key

. (For

example, the line trace frequency of 33 kHz is available by

pressing the Frequency Key.)

Figure 10: Frequency Key

Figure 11: Line Trace Frequency

Selected with Frequency Key

Activating Frequencies

Frequencies can be chosen for the set of Checked-Active

frequencies so they will be available using the Frequency

Key

.

Each frequency is activated by choosing it from a list in the

Main Menu (See Figure 13). Frequencies are grouped by

category:
Sonde

Active Line Trace

Passive Line Trace

Radio

1. Push the Menu Key

:

Figure 12: Menu Key

The Main Menu screen is then activated:

Figure 13: Main Menu

2. Using the Up and Down Keys, highlight the

frequency desired (Figure 14). In this example, the

operator is activating a 128 Hz frequency.

Figure 14: Highlighting a Desired Frequency (128 Hz)