Introduction

7

Power-On Position Recovery

Position-Trac

Certain ACU-RITE encoders, such as the ENC 150, contain closely-spaced

reference marks that enable the display to show the correct position after a
power interruption. The readout will indicate when power has been lost, and

will prompt you to move each axis until a reference mark is located. By
traversing the reference marks once in each axis, you will re-establish the
display position relative to the last known zero. The most you will ever have
to move an axis is about one inch. You must move in a positive count
direction

If you use an encoder that does not have the Position-Trac feature, the

procedure for recovering your position is slightly different. Reference marks
on these encoders are about 8 inches apart. You must find a convenient
reference mark and then use the same mark every time.

1.

Move near the desired reference mark.

2.

Press the

.

key.

3.

Move slowly past the reference mark until the readout recalls
its position. You must move in a positive direction.