VRO 300M

Readout Operations

9

0.72

1.44

2.44

Absolute zero

Shortcut

Zeroing the Displays

Absolute Zero

On many prints, dimensions are measured

from one or two surfaces of the workpiece. By
setting the readout’s absolute display to zero

at a well-chosen surface, you can enter
the part’s dimensions directly
from the print, using absolute
presets.

Setting Absolute Zero at the Current Position

1.

Move to desired location.

2.

Make sure that the absolute position is displayed.

3.

Zero the apropriate axis.

Setting Absolute Zero Using an Electronic Edge Finder

1.

Install the edge finder into the spindle and connect it to the
readout.

2.

Make sure that the absolute position is displayed.

3.

Press the zero key for the appropriate axis.

4.

Move slowly until the edge finder touches the edge
of the metal workpiece. The absolute position
display will automatically be set to zero at the
workpiece edge.

ABS

INCR

ABS

ZERO

You don’t have to worry about
overtraveling because the edge
finder probe shaft is flexible. The
readout will zero on contact.