Anchoring the segments – ACU-RITE VRO 300M User Manual

Page 55

Advertising
background image

Setup

VRO 300M

48

Anchoring the Segments

If you anchor the beginning of the first segment at a known location on the

encoder, then the segment boundary values will be the actual physical
distances from the anchor point, as shown below.

Anchoring the segments is optional: if you don’t do it, the segment boundary

values may be meaningless to you (although they are understood by the
readout).

Pressing this softkey puts the start of Segment 1 at the current

tool location. To anchor the segments correctly, move the encoder

in the negative count direction as far as it will go, then press

ANCHOR

SEGMENT 1

.

Segment 1

Segment 2

Segment 3

Segment 1

Segment 2

Segment 3

Encoder

Reading Head

Segment 1

anchored here

Segment 1

anchored here

ANCHOR

SEGMENT 1

Note: If you anchor Segment 1 in a different place after you have established
the compensation values, then the entire compensation table will be shifted to
the new anchor location, as shown below.

Segment 1

Segment 2

Segment 3

Encoder

Reading Head

Segment 1

anchored here

23.4

8.0

01 492 PPM

ENCODER 1 ERROR COMPENSATION

02 -697 PPM
03 -78 PPM

ENCODER END -- 8.00

23.4 -- ENCODER END

8.00 -- 23.4

Advertising