VRO 300M

Readout Operations

13

1.625

X 0.000 ABS

X

2

5

ENTER

6

.

1

The drill is positioned at

0.000 ABS.

Preset the absolute

location of the hole.

Absolute

zero.

1.625

-1.625

Now the drill is on the

negative side of the

hole.

Incremental zero: the

incremental display

will read 0.000 when

the drill is positioned

over the hole.

X -1.625 INCR

ABS

INCR

X 0.000 ABS

The display automatically

switches to incremental.

Presetting

When you preset a dimension, the readout places an incremental zero at the

location you specify. Then the display automatically switches to the
incremental display so that you can move to zero.

Begin a preset by pressing an axis key (

X

for

example). The information of the previous preset will
appear. The display will show you if the preset is
absolute or incremental. Use the

ABS

INCR

key to toggle

between them. Enter the dimension that you want
to preset.