ACU-RITE VRO 300M User Manual

Page 61

Advertising
background image

Setup

VRO 300M

54

RESOLUTION

10.0000

UM

DIRECTION

POSITIVE

ENCODER 1 SETUP

Encoder Setup

You must tell the readout something about the encoders. Select ENCODER
SETUP

from the Installation Setup list and enter the encoder number (the

number is defined by the input connector number on the back panel of the
readout).

The encoder number you selected is
shown at the top of the form.

R

ESOLUTION

—first use the softkeys to select

between linear and angular movement.

Linear—move the corresponding machine axis

in a positive direction until the readout senses
and displays the resolution. You won’t have to

move more than two inches. For encoders
without Position-Trac, you need to enter the
resolution in microns (µm) directly.

Angular—For an encoder used to measure angular position, enter the number
of counts per revolution.

D

IRECTION

—you can change the count direction with the

POSITIVE

and

NEGATIVE

softkeys.

Advertising
This manual is related to the following products: