81

The wire map agrees with the outlet configuration selected

for the test.

When more than one button shows at the bottom of the screen,
the tester highlights one in yellow to recommend which one to
tap. See “Buttons to Do Tests and Save Results” on page 53.

Figure 32. Wire Map Examples: Open Wire and Open Shield

GPU60.PNG

GPU61.PNG

Open

Wire 4 is open 36 m from the tester
and 14 m from the remote.

Open Shield

Shield continuity shows if you select
a shielded cable type (such as S/FTP)
on the TEST SETUP screen and you
turn on the Shield Test. The shield
in the wire map above is open 3.6 m