Versiv Cabling Certification Product Family
Technical Reference Handbook

244

If the window border is green, the measurements for the event
do not exceed the limits.

If the window border is red, a measurement exceeds the limits.

If the window border is blue, the tester does not give a pass or
fail result to the event because it cannot do a full analysis of the
event. This occurs for OTDR Port, Hidden, and End events. This
occurs for all events if you use the Document Only test limit
because Document Only does not have values for limits.

When you use a test limit that has a reflectance limit, Hidden
events show a fail status if their reflectance exceeds the limit.

: The measurement exceeds the limit.

: The measurement is within the limit.

To see details for the event, tap the window. See Figure 111 on
page 257.

To see information for another event, tap another icon on the
map.

Note

Events before the launch cord connector and after
the tail cord connector do not have a pass or fail
status.

Overall Loss: The loss of the cabling. This does not include the
OTDR connection and the loss of the last event. If Launch
Compensation
is on, the overall loss includes the launch and tail
connectors, but not the launch and tail fibers.

If you did the test at two wavelengths, the tester shows the
highest loss of the two wavelengths.

N/A shows for the Overall Loss if the tester cannot measure the
loss. This can occur when events are too close together or when
there is a large reflective event near the end of the fiber.