background image

Chapter 3: How to Certify Twisted Pair Cabling

About dB Rules

119

67 dB Rule

At frequencies where PS FEXT is less than 67 dB, PS ACR-F cannot
fail. See Tables 3 and 6 for applicable limits.

70 dB Rule

These rules applies to all channel or permanent link test limits
where ACR-F is measured.

At frequencies where FEXT is less than 70 dB for the pair used as
the receive pair for the FEXT test, ACR-F cannot fail.

See Tables 4, 5, and 6 for applicable limits.

Table 3. dB Rules for TIA Permanent Link Test Limits

Measurement

Cat 5e

Cat 6

Cat 6A

Return Loss

1

3 dB

3 dB

3 dB

NEXT

2

4 dB

4 dB

4 dB

PS NEXT

2

4 dB

4 dB

4 dB

PS ACR-N

2

4 dB

4 dB

4 dB

ACR-F

3

67 dB

1. If insertion loss is less than 3 dB, Return Loss measurements are ignored.
2. If insertion loss is less than 4 dB, these measurements are ignored.
3. If FEXT is less than 67 dB, ACR-F measurements are ignored.