Chapter 17: Specifications

CertiFiber Pro OLTS Module Specifications

381

CertiFiber Pro OLTS Loss/Length Specifications (cont.)

Specification

CertiFiber Pro

Multimode

Modules

CertiFiber Pro

Singlemode

Modules

Wavelengths

850 nm, 1300 nm, 1310 nm, 1550 nm

Power measurement range

850 nm: +10 dBm to -65 dBm
All other wavelengths: +10 dBm to -70 dBm

Display Resolution

dB, dBm: 0.01
Linear (nW, µW, mW): 0.001 to 9.999, 10.00 to
99.99, 100.0 to 999.9 depending upon value

Power measurement
uncertainty (accuracy)

 5 %  32 pW

1,2

Measurement linearity

<  0.1 dB

3

Dynamic Range for main-
remote communication and
nominal length measurement

 12 dB

 26 dB

1. 100 pW at 850 nm
2. Under the following conditions:

Power level 100 µW (-10 dBm), continuous wave (CW) for absolute power at
850 nm and 1310 nm.

Divergent beam, NA = 0.20 for 50/125 µm and NA = 0.14 for 9/125 µm.

Ambient temperature 23° ± 1 °C.

SC/UPC connector with ceramic ferrule.

After a 5 minute warm-up.

Traceable to NIST.

3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23 °C ± 1 °C. 

After a 5 minute warm-up.