Fluke Networks CertiFiber Pro Users Manual User Manual

Page 207

Advertising
background image

Chapter 7: How to Certify Fiber Cabling

Autotest in Smart Remote Mode

185

The overall result for the Autotest.

The fiber IDs and the loss and length measurements for the
fibers:

The result exceeds the limit.

The result is within the limit.

The selected test limit does not have a limit for the test.

To see the results, limits, and margins for a fiber, tap the
window. See Figure 83.

The settings the tester used for the test.

The dashed lines are around the connectors and fiber that are
included in the loss and length results. Gray connectors and
fibers are not included because you used them to set the
reference.

Connector icons show the number you entered for the TOTAL
CONNECTIONS
setting on the No. of Connectors/Splices
screen (Figure 78 on page 175). For Figure 82, the TOTAL
CONNECTIONS
setting is 4.

The round icon shows the number of splices entered for the
SPLICES setting on the No. of Connectors/Splices screen.

Bi-directional results show the fibers crossed at the main and
remote ports. The fibers show the connections as they are at the
end of the test.

To see help for the screen, tap

.

When more than one button shows at the bottom of the screen,
the tester highlights one in yellow to recommend which one to
tap. See “Buttons to Do Tests and Save Results” on page 53.

Advertising