Db rules for tia channel test limits, Db rules for iso permanent link test limits, Es 4 – Fluke Networks CertiFiber Pro Users Manual User Manual

Page 142

Advertising
background image

Versiv Cabling Certification Product Family
Technical Reference Handbook

120

Table 4. dB Rules for TIA Channel Test Limits

Measurement

Cat 5e

Cat 6

Cat 6A

Return Loss

1

3 dB

3 dB

3 dB

NEXT

2

4 dB

4 dB

4 dB

PS NEXT

2

4 dB

4 dB

4 dB

ACR-F

3

70 dB

1. If insertion loss is less than 3 dB, Return Loss measurements are ignored.
2. If insertion loss is less than 4 dB, these measurements are ignored.
3. If FEXT is less than 70 dB, ACR-F measurements are ignored.

Table 5. dB Rules for ISO Permanent Link Test Limits

Measurement

Class D

Class E

Class E

A

Class F

Class F

A

Return Loss

1

3 dB

3 dB

3 dB

3 dB

3 dB

NEXT

2

4 dB

4 dB

4 dB

4 dB

4 dB

PS NEXT

2

4 dB

4 dB

4 dB

4 dB

4 dB

ACR-N

2

4 dB

4 dB

4 dB

4 dB

4 dB

PS ACR-N

2

4 dB

4 dB

4 dB

4 dB

4 dB

ACR-F

3

70 dB

70 dB

70 dB

ACR-F

4

65 dB

65 dB

65 dB

PS ACR-F

5

70 dB

70 dB

70 dB

PS ACR-F

6

62 dB

62 dB

62 dB

1. If insertion loss is less than 3 dB, Return Loss measurements are ignored.
2. If insertion loss is less than 4 dB, these measurements are ignored.
3. If FEXT is less than 70 dB, ACR-F measurements are ignored.
4. If the calculation of the FEXT limit value at a frequency is more than 65 dB, then the

limit at that frequency is 65 dB.

5. If PSFEXT is less than 70 dB, PS ACR-F measurements are ignored.
6. If the calculation of the PSFEXT limit value at a frequency is more than 62 dB, then

the limit at that frequency is 62 dB.

Advertising