VEGA VEGASON 71 - 1 … 75 - 1 User Manual

Page 6

Advertising
background image

Technical data

Power supply

operating voltage

standard

U

nenn

= 24 V AC (16 … 42 V), 50 / 60 Hz

= 24 V DC (16 … 60 V)

option

U

nenn

= 230 V AC (90 … 250 V), 50 / 60 Hz

power consumption
at U

nenn

and max. load

12 VA / 5 W

fuse

for version

16 … 42 V AC or 16 … 60 V DC = 2 A

for version

90 … 250 V AC = 500 mA

Type

VEGASON

71 - 1

72 - 1

73 - 1

74 - 1

75 - 1

Minimum distance

at liquids or

0,3 m

0,5 m

–––

–––

–––

solids

particle size

5 mm –––

–––

0,8 m

0,8 m

1,0 m

particle size

5 mm –––

–––

1,0 m

1,1 m

1,2 m

Maximum distance

product and process dependent

5 m

5 m

10 m

20 m

30 m

Measuring data

min. measuring distance

10 cm

10 cm

10 cm

10 cm

10 cm

display in

mm

cm

cm

cm

cm

scanning

3 mm

3 mm

3 mm

3 mm

3 mm

measuring frequency

50 kHz

40 kHz

33 kHz

22 kHz

16 kHz

measuring range

0,4 sec.

0,4 sec.

0,4 sec.

0,5 sec.

0,7 sec.

angle of reflection (at –3 dB)

7

°

9

°

12

°

12

°

15

°

linearity error acc. to
empty / full adjustment

< 0,1 % of measuring range

temperature error of electronics

0,1 % / 10 k of measuring range

Sensor data

number of transducers

1

transducer housing

PVDF

impedance adapter

PE

mounting tube

type 71 … 73

PVDF, thread 1" BSP

type 74 and 75

RCH 1000, thread 1" BSP

temperature sensor

integrated in transducer

permissible excess pressure
in the vessel
- transducer 71 … 75

max. 1 bar

- transducer 71 R … 73 R

max. 1 bar

connection cable

coax line type RG 58

line length

standard

5 m

maximum

300 m

cable diameter

approx. 5 mm

Indication

LC-display

2, 4-digits each

Relay output

max. 2 modules

2 relay 1 spdt per relay each

contact material

AgCdO and Au plated

min.

turn-on voltage

10 mV

switching current

10

µ

A

max.

turn-on voltage

250 V AC, 60 V DC

switching current

2 A AC, 1 A (DC)

max.

breaking capacity

125 VA, 60 W

Technical Information

6

71 -1 … 75 - 1

Advertising