3 technical data, 1 data – VEGA VEGASCAN 850 User Manual

Page 18

Advertising
background image

18

VEGASCAN 850

Technical data

3 Technical data

3.1 Data

Power supply

Supply voltage

- VEGASCAN 850

230 V AC, 50/60 Hz

115 V AC, 50/60 Hz

- sensors

sensor power supply is provided via the
VEGASCAN 850
processing system with max.
1 … 15 sensors per two-wire cable

Min. sensor voltage

17 V

Power consumption

- VEGASCAN 850

max. 70 VA

- VEGASON 51 … 53

81 mW

- VEGASON 54 … 56

max. 1.5 W peak power
approx. 1 W continuous power

Current consumption

- VEGASON 51 … 53

6 mA

- VEGASON 54 … 56

90 mA

Resistance of the signal cable
per measuring data input

dependent on the number of connected sensors
(power) per connection cable, see following
diagram, however max. 15

W per wire

and max. 1000 m cable length

2,5 mm

2

1,5 mm

2

0

5

10

15

20

0

100

200

300

400

500

600

700

800

900

1000 m

0,75 mm

2

1,0 mm

2

630

840

23W max

Length of the connection cable

Total power of all sensors on one

two-wire cable

Note:

If longer signal cables are used, it is a good idea to distribute the sensors over two or three
inputs.

Advertising