VEGASCAN 850
39
< 100 mm
4.3 Measurement of liquids
Flat vessel top
On flat vessels, the mounting is usually done
on a very short DIN socket piece. Reference
plane is the lower edge of the flange. The
transducer should protrude out of the flange
tube.
VEGASON 55 in flange version on short
DIN socket piece
Reference plane
Mounting and installation
Min. distance
Type 54: 1 m
Type 55: 0.8 m
< 400 mm
VEGASON 56 in flange version on short
DIN socket piece
Reference plane
Min. distance
1.8 m
A mounting location directly on the vessel top
is ideal. A round opening in the vessel top is
sufficient to fasten the sensor with the flange,
or version B and C (VEGASON 54 … 56) with
swivelling holder.
VEGASON 53 on very short DIN socket piece
Reference plane
Min.
distance
£ 60 mm
VEGASON 53 (compression flange) on flat vessel top
Reference plane