VEGA VEGASCAN 850 User Manual

Page 22

Advertising
background image

22

VEGASCAN 850

Technical data

Accuracy

1)

(typical values under reference conditions relating to the nominal measuring range)

Characteristics

linear

Deviation in characteristics including

linearity, repeatability and
hysteresis (determined acc. to the
limit point method)

< 0.1 %

Linearity

better than 0.05 %

Average temperature coefficient of the

zero signal

0.06 %/10 K

Resolution

max. 1 mm

Resolution of the output signal

- VEGASON 51 … 54

0.01 % or 1 mm

- VEGASON 55 and 56

0.01 % or 10 mm

Ambient conditions

Ambient temperature (housing)

-20°C … +60°C

Process temperature (transducer)

- VEGASON 51 … 55

-40°C … +80°C (StEx: -20°C … +75°C)

- VEGASON 56 version A

-40°C … +120°C

- VEGASON 56 version B and C

-40°C … +150°C

- storage and transport temperature

-40°C … +80°C

Vessel pressure max. (gauge pressure)

- VEGASON 51 and 52

2.0 bar

- VEGASON 53

1.5 bar

- VEGASON 54

Version A

1.5 bar (flange version)

Version B … C

0.5 bar

Version D

3 bar

- VEGASON 55

Version A

1.5 bar (flange version)

Version B … C

0.5 bar

Version D

3 bar

- VEGASON 56

Version A

3 bar (flange version)

Version B … C

0.5 bar

Version D

3 bar

Protection

- sensor

IP 67

- transducer, process

IP 68

Protection class

- two-wire sensor

II

- four-wire sensor

I

Overvoltage category

III

Selfheating

at 40°C ambient temperature
- sensor

45°C

- transducer, process

55°C

1)

Similar to DIN 16 086, reference conditions acc. to IEC 770;
temperature 15°C … 35°C; moisture 45 % … 75 %; pressure 860 mbar … 1060 mbar

Advertising