VEGASCAN 850

Min. distance, max. measuring range, span and reference plane (VEGASON 54 … 56)

max. meas. distance 25 m (type 54), 45 m (type 55), 70 m (type 56)

4.2 General installation instructions

Measuring range

Beside other criteria, you select your instru-
ment according to the required measuring
range. The reference planes for the min. and
max. distance to the product or solid is the

Mounting and installation

Span

min. meas.
distance 1.0 m

min. meas. distance 0.8 m

Reference plane

max. meas. range

0 %

100 %

Span

0 %

100 %

Span

0 %

100 %

min. meas. distance 1.4 m

Reference plane

transducer end. For VEGASON 54 ... 56 in
version A the lower flange side on the sensor
is the reference plane. Please note the infor-
mation on the reference planes in chapter
"3.2 Dimensions“. The max. filling depends on
the required min. distance and the mounting
location.

Min. distance, max. measuring range and span (VEGASON 51 … 53)

4 m (type 51), 7 m (type 52), 15 m (type 53)

Full

Span

Min.
distance

1m

Empty

Min.
distance

Min.
distance

0.25 m

0.4 m

0.75 m

Reference plane

VEGASON 51

VEGASON 53

VEGASON 52

VEGASON 54
Version A

VEGASON 55
Version B

VEGASON 56
Version B

max. meas. range