9 Measured value transmission to a WEB-VV server

RS232/Ethernet connection • VEGAMET 391/624/625, VEGASCAN 693, PLICSRADIO C62

30325-EN-130701

9.4 Signal conditioning instrument (Ethernet) in

LAN

This alternative is used if a company network with internet access

is available. Any number of signal conditioning instruments can be

connected to WEB-VV. The signal conditioning instruments must be

equipped with the Ethernet interface option. When addressing is done

via DHCP, a suitable Host name should be assigned. As an alterna-

tive, a unique IP address suitable to the network can be assigned. You

can find further information in chapter "Network settings".
Prerequisites for setup:

PC with PACTware and suitable DTM as well as access to the

signal conditioning instrument via VEGACONNECT or LAN

Subnet mask, standard gateway and DNS server dof the company

network

http port 80 must be activated for an Internet connection

Start PACTware and make a connection to the signal conditioning

instrument. Select the menu item "Instrument settings - LAN/Internet".

Carry out the following steps as shown in the following illustrations.
1. Give every signal conditioning instrument a unique IP address

that you have received from your responsible network administra-

tor. The subnet mask matching your network and the standard

gateway also come from your network administrator. Alternatively,

you can use the DHCP function if a DHCP server is available in

your network.

Fig. 21: Allocate IP address

2. Enter the IP address of your DNS server under "Instrument set-

tings - DNS Server".