Fig. 5: Mounting - Version B

1

Groove to lock the housing

2

Marking notch

3

Screw of swivelling holder (hexagon SW 13)

4

Grub screw, fixing ring (hexagon spanner - size 4)

5

Terminal screws, housing (hexagon spanner - size 4)

Version C is supplied in three parts: Transducer, transducer

cable and electronics for wall mounting.
Assemble the version as follows:
1 Loosen the screws on the fixing ring (4) with a hexagon

spanner (size 4), remove the transducer tube out of the

swivelling holder

2 Mount the flange
3 Insert the transducer tube in the requested length from

below into the swivelling holder

4 Fasten with screws (4); torque max. 10 Nm
5 Remove the plug from below out of the connection head

and plug it into the socket of the transducer tube