VEGA VEGASON 66 Foundation Fieldbus User Manual

Page 34

Advertising
background image

Enter the requested parameter via the appropriate keys, save

your settings and jump to the next menu item with the [->] key.
Apart from the medium, the vessel shape can also influence

the measurement. To adapt the sensor to these measuring

conditions, this menu item offers different options depending

on whether liquid or solid is selected. With "Liquid" these are

"Storage tank", "Stilling tube", "Open vessel" or "Stirred

vessel", with "Solid", "Silo" or "Bunker".

Vessel form

Storage tank

Enter the requested parameter via the appropriate keys, save

your settings and jump to the next menu item with the [->] key.
To suppress fluctuations in the measured value display, e.g.

by fluctuating product surfaces, an integration time can be set.

This time can be between 0 and 999 seconds. Keep in mind

that also the reaction time of the complete measurement will

be bigger and the sensor will react on measured value

changes with a delay. In general a time of a few seconds will

be sufficient to smooth the measured value display.

Damping

0 s

Enter the requested parameter via the appropriate keys, save

your settings and jump to the next menu item with the [->] key.
A linearization is necessary for all vessels in which the vessel

volume does not increase linearly with the level - e.g. with a

cylindrical or spherical tank - and the indication or output of the

volume is required. Corresponding linearization curves are

preprogrammed for these vessels. They represent the

correlation between the level percentage and vessel volume.

By activating the appropriate curve, the volume percentage of

the vessel is displayed correctly. If the volume should not be

displayed in percent but e.g. in l or kg, a scaling can be also

set in the menu item "Display".

Vessel form

Damping

Linearisation curve

Setup with the indicating and adjustment module PLICSCOM

34

VEGASON 66 - Foundation Fieldbus

28795

-EN

-060731