2 principle of operation – VEGA VEGASON 66 Foundation Fieldbus User Manual

Page 9

Advertising
background image

1

2

3

4

Fig. 1: VEGASON 66 compact with swivelling holder

1

Housing cover with integrated PLICSCOM (optional)

2

Housing with electronics

3

Swivelling holder with flange

4

Transducer

3.2 Principle of operation

VEGASON 66 is an ultrasonic sensor for continuous level

measurement. It is particularly suitable for solids, but also good

for liquids.
The transducer of the ultrasonic sensor transmits short

ultrasonic pulses to the measured product. These pulses are

reflected by product surface and received again by the

rtansducer as echoes. The running time of the ultrasonic

pulases from emission to reception is proportional to the

distance and hence the level. The determined level is

converted into an appropriate output signal and outputted as

measured value.
Four-wire electronics with separate power supply.
Power for the signal output is supplied via the H1 Fieldbus. A

two-wire cable according to Fieldbus specification serves as

carrier of both power and digital data transmission for multiple

sensors. This cable can be operated in two versions:

l

via an H1 interface card in the control system and

additional power supply

l

via a Linking device with HSE (High speed Ethernet) and

additional power supply acc. to IEC 61158-2

Area of application

Physical principle

Power supply and bus com-

munication

VEGASON 66 - Foundation Fieldbus

9

Product description

28795

-EN

-060731

Advertising