VEGA VEGASOURCE 35 Emitter loading and exchange User Manual

Page 16

Advertising
background image

l

Insert the new source capsule (7) into the source holder (5) until it
snaps in or insert the spring ringe (8) with the threaded version and
screw the source capsule into the source holder (5) (torque 2
±

0.5 Nm). Use a suitable gripping device or a manipulator for

inserting

l

Insert the source holder (5) completely into the source container
and screw in with a spanner (size 13)

l

Tighten the source holder (5)

l

If necessary, remove extension rod (9)

l

Fold down the fixing strap (4)

l

Screw in the capstan screw (3) and tighten it

l

Fit the padlock (1) and lock

l

Tighten locking screw (2)

l

Secure capstan screw (3) with new seal

l

Remove existing type labels (when exchanging the emitter)

l

Unpack the type label set and letter it respectively. You can find
further information in chapter "Safety instructions - Labelling"

2

1

3

Fig. 14: Fasten type label
1

Adhesive label "Radioactive"

2

Type label - Source

3

Type label - source container (already on the source container)

l

Letter the type label (55 x 45 mm) and fasten it on the fixing strap
with four grooved pins

l

Attach the adhesive label "Radioactive" to the specified position of
the source container (if not already present)

l

Insertion or exchange of the source is hence finished

Insert source holder

Attach or replace the
type labels

16

Emitter loading and exchange • VEGASOURCE 31 35

2 Loading or emitter exchange

39155

-EN

-110210

Advertising