Correct vertical alignment of the scanning
beam. The beam lines up with the end
notches and is parallel to the long edge of
the tear bar.

Raise the validator/bracket unit to move
the scanning beam forward.Once the
beam is correctly aligned with the end
notches, tighten the four screws.

Lower the validator/bracket unit to move
the scanning beam back. Once the beam
is correctly aligned with the end notches,
tighten the four screws.

Tear Bar

Install the M4 x 6 mm screw in the right
threaded (outboard) hole and use the 3
mm allen wrench to gradually turn the
screw clockwise until the beam is parallel.

Install the M4 x 6 mm screw in the left
threaded hole and use the 3 mm allen
wrench to gradually turn the screw
clockwise until the beam is parallel.