Chapter 2

Configuring the Validator

68

The bar code was scanned five times: four scans had values of
0.51 (grade B) and one scan had a value of 0.40 (grade C).

The Decodeability grading calculation is:

(4 x 0.51) + (1 x 0.40) = 2.44

2.44 ÷ 5 = .49 (grade C)

The Overall Grade calculation is:

(4 x 3.0) + (1 x 2.0) = 14

14 ÷ 5 = 2.8 (grade B)

Modulation

NOTE:

This parameter factors into the Overall Grade (page 66).

Modulation measures how well the scan laser sees the wide
elements (bars or spaces) relative to the narrow elements. In
general, scanning lasers see bars better than spaces and wide
elements better than the narrow elements. This menu item sets the
value used by the validator for pass/fail threshold during the
analysis of bar codes. Higher values create a stricter criterion for
passing.

You can set the Modulation parameter to a percentage value from
0% to 100%. The default is 0%.

1.

Press

to take the printer offline and place the printer in

Menu mode.

2.

If necessary, press

↓ and

at the same time to unlock the

key.

3.

Press

until VALIDATOR displays.

4.

Press

↑ until Modulation displays.

5.

Press

+

or

to scroll through the percentage values: 0% to

100%. The default is 0%.

6.

Press

to select the desired value.

7.

Press

↓ and

at the same time to lock the

key, then press

PAUSE

to take the printer offline.

8.

Press

PAUSE

again to put the printer online.

..

.

..

.

Advertising