General process for barcode analysis, Chapter 2, Configuring the validator 84 – Printronix Online Data Validator User Manual

Page 84

Advertising
background image

Chapter 2

Configuring the Validator

84

General Process for Barcode Analysis

The following flow chart is an overview of how the validator
performs the barcode analysis.

Figure 26. Barcode Analysis Flowchart

Edge Determination

Reflectance Minimum <=

Threshold percentage of Reflectance

Maximum

Min. Edge Contrast (worst pair) >=

Min. Edge Contrast Threshold

Symbol Contrast >= Symbol Contrast

Threshold

Grading Scale:

A: >= 70 %
B: >= 55 %
C: >= 40 %
D: >= 20 %
F: < 20 %

Modulation >= Modulation Threshold

Grading Scale:

A: >= 70 %
B: >= 60 %
C: >= 50 %
D: >= 40 %
F: < 40 %

Defects <= Defects Threshold

Grading Scale:

A: <= 15 %
B: <= 20 %
C: <= 25 %
D: <= 30 %
F: > 30 %

Decodeability >= Decodeability

Threshold

Grading Scale:

A: >= 62 %
B: >= 50 %
C: >= 37 %
D: >= 25 %
F: < 25 %

Percent Decode >= Percent Decode

Threshold

Overall Grade >= Overall Grade

Threshold

Grading Scale:

A: 3.5 to 4.0
B: 2.5 to 3.4
C: 1.5 to 2.4
D: 0.5 to 1.4

F: 0.0 to 0.4

Advertising