The following is a sample scan report of a Code 39, 10 mil bar code
containing "*PTX8702*" with a quiet zone violation:

SCAN REPORT

ERROR: Bar code quiet zone too small

Barcode Data: [ST]PTX8702[ST]

Symbology

Code 39

Overall Grade

C (2.1)

X dimension (mils)

09.9

Decodeability (%)

65

Modulation (%)

34

Symbol Contrast (%)

68

Edge Contrast (%)

30

Defects (%)

14

Rmin/Rmax

2

PCS

92

Percent Decode (%)

100

Bar Deviation Avg (%)

-16

Min. Bar Deviation (%)

-31

Max. Bar Deviation (%)

-4

Ratio

2.0

Good Scans

28

Total Scans

30