Configuring the Validator

60

Checking Quiet Zones

Quiet zones are the white spaces surrounding the bar code. Each
bar code requires a minimum quiet zone distance in order for the
bar code to be scanned properly.

NOTE:

The validator requires a minimum distance of 1/2” or 20
times the minimum element width (x-dimension), whichever
is greater, between bar codes.

When set to Enable (the default), then the bar code quiet zone is
included as part of the pass/fail criteria.

1.

Press

to take the printer offline and place the printer in

Menu mode.

2.

If necessary, press

↓ and

at the same time to unlock the

key.

3.

Press

until VALIDATOR displays.

4.

Press

↓ until Quiet Zones displays.

5.

Press

+

or

to scroll through the choices: Enable or Disable.

The default is Enable.

6.

Press

to select the desired value.

7.

Press

↓ and

at the same time to lock the

key, then press

PAUSE

to take the printer offline.

8.

Press

PAUSE

again to put the printer online.

NOTE:

The validator does not recognize x-dimensions greater
than 40 mil with Quiet Zones enabled.

Checking the Firmware Revision Number

For troubleshooting purposes, you may need to reference the
firmware revision number.

1.

Press

to take the printer offline and place the printer in

Menu mode.

2.

If necessary, press

↓ and

at the same time to unlock the

key.

3.

Press

until VALIDATOR displays.

4.

Press

↓ until F/W Revision displays. The firmware revision

number displays.

..

.

..

.

..

.

..

.