Chapter 2

Bar Code Failures

98

Contrast too low

Check media

Data validation error: the
contrast between bars and
spaces is not sufficient. This
can be caused by too little
heat in the thermal transfer or
by use of colored media or
ribbons.

Increase Print Intensity or
reduce Print Speed in the
QUICK SETUP menu or via
host software, change
media, or set Symbol
Contrast = 0% (to disable it)
in the VALIDATOR menu.

ODV COMM ERR

See Manual

Communication error
between printer and online
data validator (ODV).

Cycle power. If the problem
persists, contact your
authorized customer service
representative.

Overall Grade

Fail

Overall data validation failure:
decodeability, percent
decode, defects, modulation,
EC Min, Rmin, and/or Symbol
Contrast.

1.

Press

PAUSE

to clear

the message.

2.

Adjust the parameter
that is causing the
failure. To see which
parameter is failing, run
a Scan Report
(page 74).

3.

Lower the Overall
Grade to a point where
the worst parameter
grade will be above the
Overall Grade
threshold.

Poor scanning

Check heat&head

Data validation failure:
decodeability. The difference
between wide and narrow
elements is too close for the
validator to reliably discern.
This usually indicates an
improperly set heat/speed/
pressure combination or the
loss of a printhead element.

1.

Adjust Print Intensity
and Print Speed in the
QUICK SETUP menu or
via host software.

2.

Adjust the printhead
pressure. (Refer to the

User’s Manual

.)

Table 6. Message List

Message

Explanation

Solution