Updating db4/db8 mkii software, Updating mainframe 6000 mkii software – TC Electronic DB8 MKII User Manual

Page 17

Advertising
background image

17

HW & installation

upDaTInG Db4/Db8 mKII sOfTware

DB4/DB8 MKII

TC ICON EDITOR

on PC OR MAC

Update Mainframe SW

X-Coupled
Ethernet cable

TV TRANSMISSION PROCESSOR /

DB-8

RESET

SUPPLY 2

SUPPLY 1

DUAL POWER REDUNDANCY

STATUS

Updating Mainframe 6000 MKII software

- Download and install TC Icon Editor on a Mac or a PC

- Download Frame, DSP & Net software to a folder on your

computer.

PC example:

Create a folder in the root directory (C), and call the

folder DB8kupdate. The path for this folder is then “

C:\

DB8update”.

Unzip and place the Frame, DSP & Net software in this

folder.

Mac example:

Create a folder on your Macintosh HD and call the folder

s6kupdate.

The path is then

“//Volumes/Macintosh HD/DB8update”.

Unzip and place the Frame, DSP & Net software in this

folder.

- Disconnect your computer from your internet router

- Connect the DB8 MKII LAN port to you computers

netcard using a X-coupled ethernet cable

- Open the TC Icon Editor, select the Frame to update and

go to the Frame/System/Update page

- Enter the path for the software:

“C:\DB8update” (for Windows)

or

“//Volumes/Macintosh HD/S6kupdate” (for Mac) as

Update Folder path

- Select Frame and press Update SW

- Select Net and press Update SW

- Select DSP and press Update SW

The Icon Editor shows the update status via a progress bar.

A log file of the update can be obtained for service

purposes. The file is saved at the location where the

software is updated from. The file lists the result of the

operation and can be opened with most text editors.

To verify correct update-procedure has taken place,

check the software version numbers both before

and after an update. These version numbers are

located on the Frame/System/Version page.