Tighten the lowest fixing screws (2) for the fixing brackets of the trolley on both sides to the
correct tightening torque. Refer to the section “Recommended tightening torques”
.

• Tighten the locking screws (1) for trolley adjustment on both sides.


Drum size

φ 355/406mm and φ 303 for low profile

c_r2bmla1c

1. Adjusting bar
2. Locking screws
3. Frame tube
4. Locking screw


• Remove the temporary transport supports. Take the hoist out of the packing and move it to the

installation site. Lift the hoist using slings around the frame tube.

• Loosen the locking (2) of adjusting bar (1). Adjust the distance between the travel wheels (A) so that it

is slightly wider than the beam flange (B) for installation purposes.

!

Do not loosen the fixing parts on the drum-side of the trolley

• Lift the hoist onto the beam. Adjust the X measurement until there is a gap of approximately 3…5mm

between the flange of the travel wheels and the flange of the beam. Use a nylon mallet to adjust the X
measurement.

• Check the wheels of the trolley are correctly aligned.

!

Tighten the locking screw (2) and (4) of the adjusting bar on both sides to the correct
tightening torque. Refer to the section “Recommended tightening torques”
.


6.3.1 Outfitting the hoist

• Install the power supply. Refer to the section “Connecting the to mains network”.

• Adjust the limit switch for hoisting. Refer to the section “Adjusting hoisting limit switch”.
• Carry out the commissioning inspection and complete the commissioning log. Refer to the section

“Commissioning”.