5.14.2 Assembly

1. Hoist limit switch
2. Connection-box cover
3. Fixing screws limit switch


Disassembly:
• Switch OFF the power supply to the hoist.

• Remove the connection-box cover (2).

• Remove the wires from the limit switch.

• Remove the fixing screws (3).
• Extract the limit switch (1).

Re-assembly:
• Fit the limit switch carefully in its place, so that the pinion fits into the gear-rim of the drum.
• Tighten the fixing screws (3)

• Re-connect the wires.

• Switch ON the power supply to the hoist and check the proper functioning of the limit switch.

!

In many cases it is necessary to re-adjust the limit switch. Be aware of incorrect settings
during testing the operation.