Drum size

φ 608 mm

c_r3gebo1a

1. Breather plug
2. Fixing screws for hoisting motor
3. Fixing screws for gearbox cover
4. Gearbox cover
5. Fixing screws for gearbox
6. Fixing plate for gearbox
7. Gearbox plug
8. Coupling


5.8.1 Service

• Check the gearbox visually for leakage.

• In case the gearbox shows signs of excessive leakage, find the reason for this and replace the worn

part, or the complete gearbox.

• Check the breather-plug breaths freely and clean if needed.

• Check for any excessive vibration and/or noise.

#

If the factory-installed grease is topped up with a different lubricant, ensure that the lubricant is
compatible. Refer to the section “Lubricants” for further instructions.


5.8.2 Assembly

See section: “Hoisting machinery, Assembly” for details.