2 components, 14 inverter – R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Plus Service Manual User Manual

Page 16

Advertising
background image

R&M Materials Handling, Inc.

4501 Gateway Boulevard

Springfield, Ohio 45502

P.: (937) 328-5100

FAX: (937) 325-5319

16/83

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

2 COMPONENTS

1.14 Inverter

Inverter (D2V) includes Power supply unit (PSU) and Control unit (CSU), which are separate parts. PSU
includes supply, brake resistor and motor connections. IGBTs are placed to PSU. Microprocessors and ASIC
are placed to CSU. Same CSU can be used in every power class.

D2V

In

1min

Imax

Weight

kg

Weight

lbs

D2V002NF1e000

6,5

10

6

13

D2V003NF1e000

8

12

6

13

D2V004NF1e000

10

15

6

13

D2V005NF1e000

13

20

6

13

D2V007NF1e000

18

27

10

22

D2V011NF1e000

24

36

10

22

D2V015NF1e000

32

48

20

44

D2V018NF1e000

42

63

20

44

D2V022NF1e000

48

72

20

44

D2V030NF1e000

60

90

37

82

D2V037NF1e000

75

113

37

82

D2V045NF1e000

90

135

37

82

D2V055NF1e000

110

165

61

135

e defines emission level ( 0 = EMC level 0, N = EMC level N/S )

The main circuit diagram of D2V002 – D2V005

L1

L2

L3

DC-

DC+

BR

B+

B-

U/T1

V/T2

W/T3

WH_G

WH_D

WL_G

WL_D

VH_G

VH_D

VL_D

UL_G

UL_D

BRK_G

BRK_D

UH_D

UH_G

VL_G

The main circuit diagram of D2V007 – D2V055

DC-

DC+

BR

B+

B-

WH_G

WH_D

WL_D

VH_G

VH_D

VL_G

VL_D

BRK_G

BRK_D

U/T1

V/T2

W/T3

L1

L2

L3

UH_D

UH_G

UL_G

UL_D

WL_G

Advertising