G4.23 Multimonitor

Multimonitor

N4.23.1.

Multimonitor page shows motor current, motor voltage and putput
frequency in display in the same time. Monitor variables can be changed
if parameter P6.5.4. = ChangeEnable

G5 Panel Control

Panel Control

B5.1.

Must not be used.

Off, On

Speed Reference

R5.2.

Speed reference for panel control

M6 System Menu

Language

S6.1.

Keypad language

English

Application

S6.2.

Application

Crane

S6.3. Copy Parameters

Parameter Sets

S6.3.1.

Not used, see parameter group G4.1. Parameter backup

Up to keypad

S6.3.2.

Save parameter settings up to keypad

Down from keypad

S6.3.3.

Download parameter settings down from keypad

Autom. BackUp

P6.3.4.

Changes in parameters are automatically saved to Keypad settings

Yes / No

S6.4. ParamComparison

Set 1

S6.4.1.

Actual parameter values are compared to Default parameters. Value of
parameters can also be changed in this display.

Par. No. = Default val.

Actual value

Set 2

S6.4.2.

Actual parameter values are compared to file User parameters. Value
of parameters can also be changed in this display.

Par. No. = User val.

Actual value

Factory settings

S6.4.3.

Parameter file Factory settings is not used

Keypad set

S6.4.4.

Actual parameter values are compared to parameter file saved in
Keypad.

S6.5. Security

Password

S6.5.1

Password for group S6.5.

Parameter lock

P6.5.2

Not used

Change Enable

Startup wizard

P6.5.3.

Not used

No

Multimon. Items

P6.5.4.

Enables or disables chancing of variables in multimonitor page
N4.23.1.

ChangeEnable

ChangeDisable

S6.6. Keypad settings

Default page

P6.6.1.

Default page to which the display automatically moves as the Timeout
time has expired or as the power is switched on to the keypad.

If the Default Page value is 0 the function is not activated, i.e. the last
displayed page remains on the keypad display.

Default page/OM

P6.6.2.

Timeout time

P6.6.3.

The time after which the keypad display returns to default page.

Contrast

P6.6.4.

Display contrast.

Backlight time

P6.6.5.

Determines how long the backlight stays before going out. Value “0”
means Forever.

0 – 65535 min

S6.7. HW settings

InternBrake Res

P6.7.1.

Must not be changed.

Not conn.

Fan Control

P6.7.2.

Must not be changed.

First start

HMI ACK timeout

P6.7.3

Not used

HMI retry

P6.7.4.

Not used

S6.8. System Info

S6.8.1. Total counters

MWh counter

C6.8.1.1.

MWh counter, can not be reseted

PwOn Day Counter

C6.8.1.2.

Total number of power on days

PwOn hour count.

C6.8.1.3.

Total number of power on hours

S6.8.2. Trip counters