R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Plus Service Manual User Manual

Page 39

Advertising
background image

R&M Materials Handling, Inc.

4501 Gateway Boulevard

Springfield, Ohio 45502

P.: (937) 328-5100

FAX: (937) 325-5319

39/83

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

045

055

2*T8, MF13ZB200, 400V 100Hz

2*T9, MF13ZC200, 400V 100Hz

Label

Code

Default

Label

Code

Default

G 2.1. General Parameters

G 2.1. General Parameters

P 2.1.10

Accel Time 1

1.5

P 2.1.10

Accel Time 1

1.5

P 2.1.11

Decel Time 1

1.5

P 2.1.11

Decel Time 1

1.5

G 2.2. Motor Parameters

G 2.2. Motor Parameters

P 2.2.1

Motor Nom Volt

400

P 2.2.1

Motor Nom Volt

400

P 2.2.2

Motor Nom Freq

100

P 2.2.2

Motor Nom Freq

100

P 2.2.3

Motor Nom Speed

2890

P 2.2.3

Motor Nom Speed

2880

P 2.2.4

Motor Nom Curr

84

P 2.2.4

Motor Nom Curr

110

P 2.2.5

Nom Flux Curr

34

P 2.2.5

Nom Flux Curr

44

P 2.2.6

Start Current

90

P 2.2.6

Start Current

110

P 2.2.7

Current Limit

126

P 2.2.7

Current Limit

165

P 2.2.8

Min Freq S1

10

P 2.2.8

Min Freq S1

10

P 2.2.9

Min Freq S2

5

P 2.2.9

Min Freq S2

5

P 2.2.10

Max Freq S1

100

P 2.2.10

Max Freq S1

100

P 2.2.11

Max Freq S2

120

P 2.2.11

Max Freq S2

120

P 2.2.12

Max ESR Freq

120

P 2.2.12

Max ESR Freq

120

P 2.2.13

Drive Selection

Hoist

P 2.2.13

Drive Selection

Hoist

P 2.2.14

Pulse Number

80

P 2.2.14

Pulse Number

80

P 2.2.15

Zero Freq Volt

0

P 2.2.15

Zero Freq Volt

0

P 2.2.16

U/f Mid Volt

8

P 2.2.16

U/f Mid Volt

6

P 2.2.17

U/f Mid Freq

0

P 2.2.17

U/f Mid Freq

0

P 2.2.18

Torque Boost

On

P 2.2.18

Torque Boost

On

P 2.2.19

Rs Voltage Drop

100

P 2.2.19

Rs Voltage Drop

100

P 2.2.20

Stop Function

Ramping

P 2.2.20

Stop Function

Ramping

G 2.3. Expert

G 2.3. Expert

P 2.3.1

Flux Current Kp

4000

P 2.3.1

Flux Current Kp

4000

P 2.3.2

Flux Current Ti

25

P 2.3.2

Flux Current Ti

25

P 2.3.3

S2 Flux Control

100

P 2.3.3

S2 Flux Control

100

P 2.3.4

Freq 0

1

P 2.3.4

Freq 0

1

P 2.3.5

Freq 1

3

P 2.3.5

Freq 1

3

P 2.3.6

Freq 2 S1

10

P 2.3.6

Freq 2 S1

10

P 2.3.7

Freq 3 S1

20

P 2.3.7

Freq 3 S1

20

P 2.3.8

Zero Flux Curr

80

P 2.3.8

Zero Flux Curr

80

P 2.3.9

Stray Flux Curr

40

P 2.3.9

Stray Flux Curr

40

P 2.3.10

Freq 2 S2

10

P 2.3.10

Freq 2 S2

10

P 2.3.11

Freq 3 S2

40

P 2.3.11

Freq 3 S2

40

P 2.3.12

Zero Speed Curr

120

P 2.3.12

Zero Speed Curr

120

P 2.3.13

Min Current Ref

90

P 2.3.13

Min Current Ref

90

P 2.3.14

Accel Comp TC

0.1

P 2.3.14

Accel Comp TC

0.1

P 2.3.15

Ref Angle S1

768

P 2.3.15

Ref Angle S1

768

P 2.3.16

Ref Angle S2

2000

P 2.3.16

Ref Angle S2

2000

P 2.3.17

Flux Curr Damp

200

P 2.3.17

Flux Curr Damp

200

P 2.3.18

Stop DC-Freq

1.5

P 2.3.18

Stop DC-Freq

1.5

P 2.3.19

Start Freq S1

1

P 2.3.19

Start Freq S1

1

P 2.3.20

Start Freq S2

0.5

P 2.3.20

Start Freq S2

0.5

P 2.3.21

Brake Stop Freq

1

P 2.3.21

Brake Stop Freq

1

P 2.3.22

ESR Point Freq

120

P 2.3.22

ESR Point Freq

120

P 2.3.23

ESR Point Volt

120

P 2.3.23

ESR Point Volt

120

P 2.3.24

IrAdd Motor

100

P 2.3.24

IrAdd Motor

100

P 2.3.25

IrAdd Generator

100

P 2.3.25

IrAdd Generator

100

P 2.3.26

Ramp Stretching

0

P 2.3.26

Ramp Stretching

0

P 2.3.27

Switching Freq

3.6

P 2.3.27

Switching Freq

3.6

P 2.3.28

DeadTime Comp

2200

P 2.3.28

DeadTime Comp

2200

P 2.3.29

DeadTimeCurrLim

100

P 2.3.29

DeadTimeCurrLim

100

P 2.3.30

Brake Chopper

Run

P 2.3.30

Brake Chopper

Run

Advertising