G4.7. Digital Input

S1

V4.7.1.1.

State of digital input S1

0=OFF, 1=ON

S2

V4.7.1.2.

State of digital input S2

0=OFF, 1=ON

DIA3

V4.7.1.3.

State of digital input DIA3

0=OFF, 1=ON

DIA4

V4.7.1.4.

State of digital input DIA4

0=OFF, 1=ON

DIA5

V4.7.1.5.

State of digital input DIA5

0=OFF, 1=ON

OK

V4.7.1.6.

State of digital input OK

0=OFF, 1=ON

DID1

V4.7.1.7.

State of digital input DID1

0=OFF, 1=ON

DID2

V4.7.1.8.

State of digital input DID2

0=OFF, 1=ON

DID3

V4.7.1.9.

State of digital input DID3

0=OFF, 1=ON

DID4

V4.7.1.10.

State of digital input DID4

0=OFF, 1=ON

DID5

V4.7.1.11.

State of digital input DID5

0=OFF, 1=ON

Basic Board

V4.7.3.

State of board A inputs

Corresponding X1 terminals

S1

8

S2

9

DIA3

10

DIA4

11

DIA5

12

0=OFF, 1=ON

Extension Board

V4.7.4.

State of board D inputs

Corresponding X1 terminals

DID1

38

DID2

39

DID3

40

DID4

41

DID5

42

0=OFF, 1=ON

G4.8. SSU

Overspd Lim 1

V4.8.1.

Overspeed limit 1 level. Percent of Max Freq S2

0 – 140 %

Overspd Lim 2

V4.8.2.

Overspeed limit 2 (ESR) value. Percent of Max Freq S2

0 – 140 %

G4.9. Service

Phase U Curr

V4.9.1.

Phase U current of inverter output

A

Phase V Curr

V4.9.2.

Phase V current of inverter output

A

Phase W Curr

V4.9.3.

Phase W current of inverter output

A

Encoder Speed

V4.9.4.

Pulse frequency from pulse sensor. Both A and B channel must be in
use.

Hz

HeatSinkTempMax

V4.9.5.

Recorded heatsink temperature highest peak value during run.

°

C

HeatSinkTempMin

V4.9.6.

Recorded heatsink temperature lowest peak value when power is
connected to drive.

°

C

IGBT Temp Max

V4.9.7.

Recorded calculated IGBT temperature highest peak value.

°

C

IGBT Temperature

V4.9.8.

Actual IGBT temperature

°

C

SlipAdjustChange

V4.9.9.

Slip adjust difference compared to Slip adjust parameter.

%

G4.9.10 Max Current.

Max Current

G4.9.10.1.

Recorded maximum current

A

Max Current Freq

G4.9.10.2.

Frequency at recorded maximum current.

Hz

Max Current Torq

G4.9.10.3.

Torque at recorded maximum current.

%

G4.9.11 Encoder

V4.9.11.1

Not used.

V4.9.11.2

Not used.

V4.9.11.3

Not used.

V4.9.11.4

Not used.

V4.9.11.5

Not used.

Freq Ref

V4.11.

Frequency reference

Hz

Speed Req

V4.12.

Not used.

Distance counter

V4.13.

Not used

m

DC-Link Voltage

V4.14.

Actual value of measured DC-link voltage.

V

Heat Sink Temp

V4.15.

Temperature of heat sink.

°

C

MotorTemperature

V4.16.

Calculated motor temperature in percent of maximum

%

Motor Power

V4.17.

Calculated actual power. % of nominal power of unit

%

Motor Voltage

V4.18.

Calculated motor voltage

V

Motor Torque

V4.19.

Calculated motor torque

+/- motor nominal torque, positive when motoring, negative when
generating.

%

Motor Current

V4.20.

Measured motor current

A

Motor speed

V4.21

Calculated motor speed

Rpm

Output frequency

V4.22

Output frequency to the motor

Hz

Advertising