Inverter needs information about the motor rotation speed for stall, speed difference and over speed supervision. Type
markings of the speed supervision sensors (not needed in applications with bearing sensor or encoder) and fixing
distance from the pulse wheel (air gap) are shown in the table below.

Proximity switch

air gap

Honeywell 3GT101DC

5

12

35

29

Honeywell 3GT101DC

0.5 ... 1.0 mm

Schönbuch INSOR88 ICDM 8802

0.5 ± 0.1 mm

Baumer IFRM08N1501/L

0.5 ± 0.1 mm

Note that the Honeywell-sensor cable is lengthened and the wire colours are not equal to other
sensors. However, colour markings corresponding to the other sensors have been added to
wire ends (not necessarily, if cable has been shortened afterwards). The connection of
Honeywell-sensor and the cable markings are shown in the table below.

Signal name

Sensor

Cable

Colour marking

Terminal number

+24V

Red

Brown

Brown

KAE234:6

PULSE

Green

Green

Black

KAE234:1

40

8

Schönbuch INSOR ICDM 8802

0V

Black

White

Blue

KAE234:2

Red

Green

Black

Brown

Green

White

6

1

2

3

4

7

+

0V

+15V

OUT

0V

Honeywell 3GT101DC

A5

IN

V

E

R

T

E

R

+24V

EA+

OV

Brown

Black

Blue

6

1

2

3

4

7

+

0V

+15V

OUT

0V

A5

IN

V

E

R

T

E

R

+24V

EA+

OV

M8x1

30

Baumer IFRM08N1501/L


Note the following details
-

buffer amplifier must be located as close the proximity switch as possible (maximum distance 3m)

-

sensor cable must be located as far from the motor cables and braking resistor cable as possible (minimum distance
> 20cm)

In order to avoid fault situations, the cable between the encoder and inverter must be

-

as far as possible from the cables of motor and braking resistor (minimum distance >20cm)

-

a shielded and twisted cable

-

grounded (the shield) at both ends, 360

°

grounding on inverter terminal

-

the shield should be grounded always when going through terminals


Some problems may occur when using shielded flat cable or in situations where the encoder cable has been placed too
close (< 5cm) to the motor cables and braking resistor cables. Cabling methods and distances determine the best way to
ground the shielded cable; at both ends or only at one end.

Buffer amplifier pulse output can be measured during driving. If the pulse sequence is not uniform and for instance longer
pulses occur every now and then, the reason may be one of following:
-

an incorrect air gap (proximity switch)

-

the sensor is not properly on the top of the pulse wheel (proximity switch)

-

disturbances are transferred to the sensor cable

-

the pulse wheel is faulty


Honeywell 3GT101DC Hall-sensor requires tooth movement past the sensor. A motionless tooth can not generate a
pulse.